IST

IST distillation units

Recycling of contaminated solvents from small to large quantities. IST, ECO PLUS, ROTO PLUS, ROTO NEXT and HR series.

Models (8)

Sorted by “Distillation output”, lowest value first.

  • IST C1-C2

    Small IST C1 and C2 solvent recovery units for low and occasional solvent consumption – 1.6 kW, fill 10 or 15 l.

    10–60 l/24 hDistillation output

    Loading capacity
    10 – 15 l
  • IST 32-62

    Small industrial IST 32 and IST 62 solvent recovery units for regular solvent consumption – fill 30 or 62 l, 30–240 l/24 h.

    30–240 l/24 hDistillation output

    Loading capacity
    30 – 62 l
  • ROTO NEXT 100-202-400

    IST ROTO NEXT 100-202-400 solvent distillation unit in ATEX II2G design – successor to ROTO PLUS with gravimetric filling and insulated vessel, 100 – 2,000 l/24 h.

    100–2,000 l/24 hDistillation output

    Loading capacity
    100 – 400 l
  • ROTO PLUS 100-202-400

    Modular self-cleaning IST ROTO PLUS 100-202-400 solvent distillation unit in ATEX II2G design – automatic unattended operation, 100 – 2,000 l/24 h.

    100–2,000 l/24 hDistillation output

    Loading capacity
    100 – 400 l
  • ECO PLUS 202-400

    Expandable IST ECO PLUS 202-400 solvent recovery unit in ATEX II2G version for continuous operation – up to 2,000 l of contaminated product per day.

    200–2,000 l/24 hDistillation output

    Loading capacity
    200 – 400 l
  • HR 600-1200

    Fully automatic IST HR 600 / HR 1200 vacuum solvent recovery unit for industrial operations – continuous distillation including filling and sludge discharge.

    600–10,000 l/24 hDistillation output

    Loading capacity
    1,200 – 580 l
  • IST 90

    IST 90 solvent recovery unit for medium to large companies – fill 90 l, 90–360 l/24 h, multiple cycles with sludge accumulation, N-DIGIT or ATEX II2G.

    90–360 l/24 hTypical application 90 to 360 l /24 h

    Loading capacity
    90 l
  • IST 202

    IST 202 solvent recovery unit for medium to large companies – fill 200 l, 200–800 l/24 h, multiple cycles with sludge accumulation, N-DIGIT or ATEX II2G.

    200–800 l/24 hTypical application 200 to 800 l /24 h

    Loading capacity
    200 l

Also searched as: distiller, distillers, distillation unit, solvent distillation, solvent recycling

How it works

How solvent distillation works

The contaminated solvent is heated in the boiler, its volatile fraction evaporates, turns back into a liquid in the condenser and flows out as clean solvent. The contaminants remain in the boiler as residue.

How solvent distillation worksContaminated solventVacuumBoilerOil heatingResidueCondenserAir / water coolingClean solvent
How solvent distillation worksContaminated solventVacuumBoilerOil heatingResidueCondenserAir / water coolingClean solvent
  • Contaminated liquid
  • Negative pressure (vacuum)
  • Heat
  • Residue for disposal
  • Vapour
  • Cooling
  • Clean liquid
Description of all parts
  1. Filling

    The contaminated solvent is filled into the boiler – depending on the machine, manually, with a filling kit or automatically from a storage tank.

    • Contaminated solvent
      Solvent contaminated with paints, resins and the like – for example from cleaning spray guns and containers.
  2. Heating and evaporation

    Thermal oil transfers heat to the boiler. The volatile fraction of the solvent evaporates; the less volatile contaminants remain in the boiler. Some series operate under vacuum.

    • Vacuum (some series)
      In some series (IST 90, IST 202, ECO PLUS, ROTO PLUS, HR), a vacuum pump lowers the boiling point of the solvent. IST uses a liquid-ring vacuum pump.
      A lower boiling point means less thermal stress – suitable for high-boiling and heat-sensitive solvents. For nitrocellulose paints, IST recommends vacuum distillation.
    • Distillation unit boiler
      A sealed boiler in which the solvent evaporates and the contaminants remain. Some series have an agitator with scrapers that keeps the boiler walls clean.
      Distillation only changes the physical state – the chemical properties of the solvent are retained, so it can be distilled repeatedly. IST has replaced the PTFE coating with a surface treatment of the boiler that is similarly non-stick and more wear-resistant.
      How solvent recycling by distillation works →
    • Thermal oil heating
      Heat is transferred to the boiler by thermal (diathermic) oil – not by a direct flame or a heating coil in the solvent.
      According to IST, oil heating is more efficient than steam or hot water. Smaller machines use static oil; the HR series has a modulating heater with an oil circulation pump.
  3. Condensation

    The vapours pass into the condenser, which removes their heat – the solvent returns to liquid form. The condenser is cooled by air or water.

    • Condenser
      Removes heat from the vapour so that the solvent turns back into a liquid.
      The condenser material must be compatible with the solvent being distilled.
    • Air or water cooling
      An air-cooled condenser depends on the room temperature and ventilation; a water-cooled one allows more stable conditions.
  4. Clean solvent

    The condensed solvent is collected in a container. Whether it is suitable for reuse depends on its composition and on the process in which it is to be used.

    • Clean solvent
      The distillate is collected in a container and can be reused, for example for cleaning.
      Less new solvent and less waste – and less dependence on suppliers.
  5. Residue

    At the end of the cycle, the concentrated residue is removed from the boiler – depending on the machine, by tilting the boiler into a bag, via a valve or automatically.

    • Residue for disposal
      The concentrated residue (sludge) from the boiler is disposed of as waste. Its volume is much smaller than that of the original contaminated solvent.
      The residue consists of resins, polymers, metals and other non-volatile substances; depending on its composition, it is hazardous waste. It is emptied by tilting the boiler into a bag (IST C, 32–62), via a valve (IST 90, 202) or automatically (HR).

Simplified principle, not the layout of a specific model. The filling, emptying and cooling method, and whether the machine operates under vacuum, vary by series – we specify them in our quotation.

Source: IST – description of the distillation process in 5 steps and the distillation unit pages (ist.it).

Model comparison

Model comparison: IST distillation units
ModelLoading capacityDistillation outputOutputExplosion protection
IST C1-C210 – 15 l10–60 l/24 h1.6 kW–
IST 32-6230 – 62 l30–240 l/24 hby version–
ROTO NEXT 100-202-400100 – 400 l100–2,000 l/24 h10 – 22 kWATEX II2G
ROTO PLUS 100-202-400100 – 400 l100–2,000 l/24 h10 – 22 kWATEX II2G
ECO PLUS 202-400200 – 400 l200–2,000 l/24 h12 – 22 kWATEX II2G
HR 600-12001,200 – 580 l600–10,000 l/24 h44 – 66 kW–
IST 9090 l–8 kW–
IST 202200 l–15 kW–

Data are taken from manufacturer documentation. We will verify them for your application before you order.

Frequently asked questions

Who sells IST solvent recovery units and washing equipment in Slovakia and the Czech Republic?

TECHNIKUM is the IST authorised distributor for Slovakia and the Czech Republic – solvent distillation and parts washing. Services: sales and service. All brands: Manufacturers we represent.

Have a different question? Write to us – a technician will answer. Send an enquiry

Technical terms are explained in the glossary.

Call TECHNIKUM, +421 33 5521 123Send an enquiry