IST
IST 90
IST 90 solvent recovery unit for medium to large companies – fill 90 l, 90–360 l/24 h, multiple cycles with sludge accumulation, N-DIGIT or ATEX II2G.
Who it is for: regeneration of used solvents, paint shops and painting lines, printing works, paint and varnish manufacturing
- 90 lLoading capacity
- 8 kWOutput
- 90–360 l/24 hTypical application 90 to 360 l /24 h
Enquire about this productSend a solvent sample – we will test the recycling
The technician for your field will contact you as soon as possible. Prices are provided in our quotation.
Why IST 90
- Several cycles in a rowDistillation with sludge accumulation and easy discharge through a 3" valve at the end.
- Precise vacuum controlCentrally controlled vacuum pump and recirculating chiller, stable parameters for repeatable results.
- Energy savingsIntelligent temperature control saves resources.
- Indoor and outdoor installationCompact, robust design; in the ATEX II2G version also directly in ATEX zones.
- Convenient operationErgonomic interface and option to tilt the machine.
IST 90 is a solvent recovery unit for medium to large companies on the boundary between medium volumes and large-scale industrial operation. It can be set to run several cycles in a row with sludge accumulation, and the sludge is finally discharged easily through a manual 3" valve. Heating is by static oil, the vacuum pump and recirculating chiller are centrally controlled and the vacuum is precisely regulated. The compact and robust design can be installed indoors or outdoors, and the machine can be tilted for operator convenience. All cycle parameters, including temperatures, are always shown on the PLC touch display. It is available in the N-DIGIT version for non-classified areas and in the ATEX II2G version, where the PLC is housed in an explosion-proof enclosure on the machine, so it can be installed directly in ATEX zones.
Source of text: manufacturer’s brochure (PDF, in English)
Technical data
- Typical application 90 to 360 l /24 h
- 90–360 l/24 h
- Output
- 8 kW
- Loading capacity
- 90 l
Further manufacturer data
- Version
- N-DIGIT (Installation: NON-CLASSIFIED AREA); ATEX II2G
Data are taken from manufacturer documentation. We will verify them for your application before you order. Request a technical data sheet
How it works
How solvent distillation works
The contaminated solvent is heated in the boiler, its volatile fraction evaporates, turns back into a liquid in the condenser and flows out as clean solvent. The contaminants remain in the boiler as residue.
Select a step or click a part of the diagram – we will show what it does, related terms, questions and products.
- Contaminated liquid
- Negative pressure (vacuum)
- Heat
- Residue for disposal
- Vapour
- Cooling
- Clean liquid
Description of all parts
- Filling
The contaminated solvent is filled into the boiler – depending on the machine, manually, with a filling kit or automatically from a storage tank.
- Contaminated solvent
Solvent contaminated with paints, resins and the like – for example from cleaning spray guns and containers.
- Contaminated solvent
- Heating and evaporation
Thermal oil transfers heat to the boiler. The volatile fraction of the solvent evaporates; the less volatile contaminants remain in the boiler. Some series operate under vacuum.
- Vacuum (some series)
In some series (IST 90, IST 202, ECO PLUS, ROTO PLUS, HR), a vacuum pump lowers the boiling point of the solvent. IST uses a liquid-ring vacuum pump.
A lower boiling point means less thermal stress – suitable for high-boiling and heat-sensitive solvents. For nitrocellulose paints, IST recommends vacuum distillation. - Distillation unit boiler: IST 90
A sealed boiler in which the solvent evaporates and the contaminants remain. Some series have an agitator with scrapers that keeps the boiler walls clean.
Distillation only changes the physical state – the chemical properties of the solvent are retained, so it can be distilled repeatedly. IST has replaced the PTFE coating with a surface treatment of the boiler that is similarly non-stick and more wear-resistant.
How solvent recycling by distillation works → - Thermal oil heating
Heat is transferred to the boiler by thermal (diathermic) oil – not by a direct flame or a heating coil in the solvent.
According to IST, oil heating is more efficient than steam or hot water. Smaller machines use static oil; the HR series has a modulating heater with an oil circulation pump.
- Vacuum (some series)
- Condensation
The vapours pass into the condenser, which removes their heat – the solvent returns to liquid form. The condenser is cooled by air or water.
- Condenser
Removes heat from the vapour so that the solvent turns back into a liquid.
The condenser material must be compatible with the solvent being distilled. - Air or water cooling
An air-cooled condenser depends on the room temperature and ventilation; a water-cooled one allows more stable conditions.
- Condenser
- Clean solvent
The condensed solvent is collected in a container. Whether it is suitable for reuse depends on its composition and on the process in which it is to be used.
- Clean solvent
The distillate is collected in a container and can be reused, for example for cleaning.
Less new solvent and less waste – and less dependence on suppliers.
- Clean solvent
- Residue
At the end of the cycle, the concentrated residue is removed from the boiler – depending on the machine, by tilting the boiler into a bag, via a valve or automatically.
- Residue for disposal
The concentrated residue (sludge) from the boiler is disposed of as waste. Its volume is much smaller than that of the original contaminated solvent.
The residue consists of resins, polymers, metals and other non-volatile substances; depending on its composition, it is hazardous waste. It is emptied by tilting the boiler into a bag (IST C, 32–62), via a valve (IST 90, 202) or automatically (HR).
- Residue for disposal
Simplified principle, not the layout of a specific model. The filling, emptying and cooling method, and whether the machine operates under vacuum, vary by series – we specify them in our quotation.
Source: IST – description of the distillation process in 5 steps and the distillation unit pages (ist.it).
Similar models – IST distillation units

IST
IST 202
IST 202 solvent recovery unit for medium to large companies – fill 200 l, 200–800 l/24 h, multiple cycles with sludge accumulation, N-DIGIT or ATEX II2G.
200–800 l/24 hTypical application 200 to 800 l /24 h
- Loading capacity
- 200 l

IST
IST 32-62
Small industrial IST 32 and IST 62 solvent recovery units for regular solvent consumption – fill 30 or 62 l, 30–240 l/24 h.
30–240 l/24 hDistillation output
- Loading capacity
- 30 – 62 l

IST
HR 600-1200
Fully automatic IST HR 600 / HR 1200 vacuum solvent recovery unit for industrial operations – continuous distillation including filling and sludge discharge.
600–10,000 l/24 hDistillation output
- Loading capacity
- 1,200 – 580 l

IST
IST C1-C2
Small IST C1 and C2 solvent recovery units for low and occasional solvent consumption – 1.6 kW, fill 10 or 15 l.
10–60 l/24 hDistillation output
- Loading capacity
- 10 – 15 l
Frequently asked questions
How much solvent does IST 90 recycle?
According to the manufacturer's technical data for IST 90: typical use 90–360 l/24 h; filling volume 90 l.
What is the installed power of IST 90?
According to the manufacturer's technical data for IST 90: installed power 8 kW.
Is IST 90 available in a version for potentially explosive atmospheres (ATEX)?
Yes, in the ATEX II2G version; the N-DIGIT version is intended for installation outside potentially explosive atmospheres.
Have a different question? Write to us – a technician will answer. Send an enquiry
Technical terms are explained in the glossary.