Article
How to choose an Airless and AirCoat nozzle: angle, orifice, filter and wear
Published
The nozzle determines the fan width, the amount of material and the surface quality. We explain what the numbers on the nozzle mean, how to choose the angle, orifice and filter, and how to tell that a nozzle is worn.

What the nozzle designation means
The number on an Airless nozzle indicates both the spray angle and the orifice size. The first digit multiplied by ten is the angle in degrees, the next two digits are the orifice diameter in thousandths of an inch. Nozzle 517 therefore has an angle of 50° and an orifice of 0.017″, which is 0.43 mm.
WAGNER AirCoat nozzles are designated the other way round – first the orifice, then the angle. The designation 17/50 means an orifice of 0.017″ and an angle of 50°, i.e. the same parameters as 517 for Airless.
The spray angle determines the fan width
The spray angle determines how wide a fan the nozzle applies. WAGNER gives a rule of thumb: angle × 5 is the approximate spray width in millimetres at a distance of about 30 cm from the part. A nozzle with a 50° angle thus gives a fan roughly 25 cm wide.
| Spray angle | Width – WAGNER Tip | Width – ACF 3000 |
|---|---|---|
| 20° | 104 mm | 100 mm |
| 30° | 152 mm | 145 mm |
| 40° | 203 mm | 195 mm |
| 50° | 254 mm | 250 mm |
| 60° | 305 mm | 300 mm |
| 80° | 406 mm | 400 mm |
Choose the angle according to the size and shape of the part. A narrow fan is suitable for frames, edges and smaller parts, a wide one for large surfaces. The width is also affected by the gun distance: when the gun is further from the surface, the jet widens, the edges become thinner and overspray increases; when it is too close, the coat is thick and the material runs.
The nozzle orifice determines the flow rate
The orifice diameter determines how much material the nozzle lets through per minute. The flow rate does not depend on the angle: nozzles 217 and 517 have the same orifice and therefore the same flow rate, they just spread it over a fan of different width. WAGNER states the flow rate measured with water at a pressure of 100 bar; actual paint with a higher viscosity flows differently.
| Orifice (code) | Diameter | Flow rate | Material filter |
|---|---|---|---|
| 09 | 0.009″ / 0.23 mm | 0.26 l/min | 200 mesh |
| 11 | 0.011″ / 0.28 mm | 0.38 l/min | 200 mesh |
| 13 | 0.013″ / 0.33 mm | 0.55 l/min | 200 or 100 mesh |
| 15 | 0.015″ / 0.38 mm | 0.75 l/min | 100 mesh |
| 17 | 0.017″ / 0.43 mm | 0.96 l/min | 100 mesh |
| 19 | 0.019″ / 0.48 mm | 1.20 l/min | 100 or 50 mesh |
| 21 | 0.021″ / 0.53 mm | 1.45 l/min | 50 mesh |
| 25 | 0.025″ / 0.64 mm | 1.92 l/min | 50 mesh |
| 31 | 0.031″ / 0.79 mm | 2.95 l/min | 30 mesh |
The values differ slightly between nozzle ranges, so always use the table for the specific range when choosing. The complete tables are given for each range in the catalogue, for example for the WAGNER Tip nozzles.
How the orifice relates to the material
The orifice size is chosen according to the material and the surface. According to WAGNER, the viscosity of the material also determines atomisation. Thicker and filled materials are sprayed with larger orifices, and these go with coarser filters. Ranges with large orifices are designed for high-build coatings.
A test spray onto cardboard verifies that the choice is correct. If the fan has stripes at the edges or is uneven, WAGNER recommends proceeding in this order:
- increase the pressure – the nozzle receives more material and the fan evens out,
- thin the material if it is too thick,
- choose a different nozzle size or check whether it is worn.
With AirCoat, the atomising (shaping) air is also tried before increasing the material pressure.
Material filter according to the orifice
The material filter catches impurities before they clog the nozzle, and its fineness depends on the orifice. The higher the mesh number, the finer the filter: small orifices need 200 mesh, large ones 30 mesh. For a borderline orifice, the catalogue gives two finenesses – for example, for orifice 13 it is 200 or 100 mesh. In that case, choose the finer filter if the material passes through it without clogging; the coarser one is for materials with coarser pigment or filler that a fine filter would retain.
With AirCoat, filtering takes place twice – with a slot filter in the high-pressure filter and with a filter in the gun. For ACF 3000 nozzles, the catalogue recommends:
- slot filter: 200 mesh for orifices 07–11, 100 mesh for 11–17, 60 mesh for 17–23,
- filter in the gun: 200 mesh for 07–11, 150 mesh for 11–13, 100 mesh for 13–19, 50 mesh for 19–23.
Nozzle wear: when to replace it
A worn nozzle uses more material than it should and sprays a poorer fan with more overspray. The orifice gradually enlarges due to the material: the fan narrows and the flow rate increases, so more paint goes onto a smaller area. According to WAGNER, the wear cannot be seen from the outside, so it only shows in the result and in paint consumption.
Replace the nozzle when the test spray does not turn out right even with the correct pressure and thinning, or when material consumption increases for the same work. For HEA nozzles, WAGNER states that a lower working pressure extends their service life by up to two times. According to WAGNER, AirCoat nozzles are made of carbide.
Reversible nozzles and nozzles with pre-atomiser
The PROTEC Tip reversible nozzle can be turned round so that a clogged orifice is blown clear by the material pressure itself without dismantling. The PROTEC range goes up to an orifice of 0.065″ (1.65 mm) with a flow rate of 9 l/min and is therefore used for high-build coatings.
The AirCoat ACF 3000 plus range has a pre-atomiser and its own orifice sizes from 08 to 22 with angles of 20–60°. The ACF 3000 S2 range, whose nozzles keep the same angle even after replacement, is designed for automatic lines, and the ACF 5000 range for electrostatic AirCoat guns. With manual AirCoat guns, the fan width can be fine-tuned with the shaping air.
From the part to the nozzle and filter
Start from the part and the material: the fan width determines the angle, the material and the required coat determine the orifice, and choose the filter to match the orifice. Tables for all ranges can be found in the WAGNER nozzles category. If you are not sure, send us the technical data sheet of the material and we will recommend a nozzle.
Is this an issue in your plant?
Tell us what you need – the technician for your area will get back to you.
Your technician
Peter Kovár
WAGNER Sales Manager | SK & CZ
- Phone – Peter Kovár: +421 911 804 818
- E-mail – Peter Kovár: kovar@
technikum.sk - Speaks: Slovak, Czech
Do you have a question on this topic?The AI adviser answers immediately
Your technician
Peter Kovár
WAGNER Sales Manager | SK & CZ
- Phone – Peter Kovár: +421 911 804 818
- E-mail – Peter Kovár: kovar@
technikum.sk - Speaks: Slovak, Czech
Frequently asked questions
What does the number on an Airless nozzle mean?
The number on an Airless nozzle indicates both the spray angle and the orifice size. The first digit multiplied by ten is the angle in degrees, the next two digits are the orifice diameter in thousandths of an inch. Nozzle 517 therefore has an angle of 50° and an orifice of 0.017″, which is 0.43 mm.
How does the spray angle relate to the fan width?
The spray angle determines how wide a fan the nozzle applies. WAGNER gives a rule of thumb: angle × 5 is the approximate spray width in millimetres at a distance of about 30 cm from the part. A nozzle with a 50° angle thus gives a fan roughly 25 cm wide.
When does an Airless nozzle need to be replaced?
A worn nozzle uses more material than it should and sprays a poorer fan with more overspray. The orifice gradually enlarges due to the material: the fan narrows and the flow rate increases, so more paint goes onto a smaller area. According to WAGNER, the wear cannot be seen from the outside, so it only shows in the result and in paint consumption.
Have a different question? Write to us – a technician will answer. Send an enquiry
Technical terms are explained in the glossary.