Article

How to choose an Airless and AirCoat nozzle: angle, orifice, filter and wear

Published

The nozzle determines the fan width, the amount of material and the surface quality. We explain what the numbers on the nozzle mean, how to choose the angle, orifice and filter, and how to tell that a nozzle is worn.

Gloved hand holding a WAGNER spray gun with a nozzle emitting a spray of paint
WAGNER manual spray gun · Photo: WAGNER

What the nozzle designation means

The number on an Airless nozzle indicates both the spray angle and the orifice size. The first digit multiplied by ten is the angle in degrees, the next two digits are the orifice diameter in thousandths of an inch. Nozzle 517 therefore has an angle of 50° and an orifice of 0.017″, which is 0.43 mm.

WAGNER AirCoat nozzles are designated the other way round – first the orifice, then the angle. The designation 17/50 means an orifice of 0.017″ and an angle of 50°, i.e. the same parameters as 517 for Airless.

The spray angle determines the fan width

The spray angle determines how wide a fan the nozzle applies. WAGNER gives a rule of thumb: angle × 5 is the approximate spray width in millimetres at a distance of about 30 cm from the part. A nozzle with a 50° angle thus gives a fan roughly 25 cm wide.

Spray width by angle – WAGNER Tip (Airless) and ACF 3000 (AirCoat); measured 30 cm from the object at 110 bar with a 56 s paint (DIN 4)
Spray angleWidth – WAGNER TipWidth – ACF 3000
20°104 mm100 mm
30°152 mm145 mm
40°203 mm195 mm
50°254 mm250 mm
60°305 mm300 mm
80°406 mm400 mm

Choose the angle according to the size and shape of the part. A narrow fan is suitable for frames, edges and smaller parts, a wide one for large surfaces. The width is also affected by the gun distance: when the gun is further from the surface, the jet widens, the edges become thinner and overspray increases; when it is too close, the coat is thick and the material runs.

The nozzle orifice determines the flow rate

The orifice diameter determines how much material the nozzle lets through per minute. The flow rate does not depend on the angle: nozzles 217 and 517 have the same orifice and therefore the same flow rate, they just spread it over a fan of different width. WAGNER states the flow rate measured with water at a pressure of 100 bar; actual paint with a higher viscosity flows differently.

Orifice, flow rate and recommended material filter – WAGNER Tip Airless nozzles (flow rate with water at 100 bar)
Orifice (code)DiameterFlow rateMaterial filter
090.009″ / 0.23 mm0.26 l/min200 mesh
110.011″ / 0.28 mm0.38 l/min200 mesh
130.013″ / 0.33 mm0.55 l/min200 or 100 mesh
150.015″ / 0.38 mm0.75 l/min100 mesh
170.017″ / 0.43 mm0.96 l/min100 mesh
190.019″ / 0.48 mm1.20 l/min100 or 50 mesh
210.021″ / 0.53 mm1.45 l/min50 mesh
250.025″ / 0.64 mm1.92 l/min50 mesh
310.031″ / 0.79 mm2.95 l/min30 mesh

The values differ slightly between nozzle ranges, so always use the table for the specific range when choosing. The complete tables are given for each range in the catalogue, for example for the WAGNER Tip nozzles.

How the orifice relates to the material

The orifice size is chosen according to the material and the surface. According to WAGNER, the viscosity of the material also determines atomisation. Thicker and filled materials are sprayed with larger orifices, and these go with coarser filters. Ranges with large orifices are designed for high-build coatings.

A test spray onto cardboard verifies that the choice is correct. If the fan has stripes at the edges or is uneven, WAGNER recommends proceeding in this order:

  • increase the pressure – the nozzle receives more material and the fan evens out,
  • thin the material if it is too thick,
  • choose a different nozzle size or check whether it is worn.

With AirCoat, the atomising (shaping) air is also tried before increasing the material pressure.

Material filter according to the orifice

The material filter catches impurities before they clog the nozzle, and its fineness depends on the orifice. The higher the mesh number, the finer the filter: small orifices need 200 mesh, large ones 30 mesh. For a borderline orifice, the catalogue gives two finenesses – for example, for orifice 13 it is 200 or 100 mesh. In that case, choose the finer filter if the material passes through it without clogging; the coarser one is for materials with coarser pigment or filler that a fine filter would retain.

With AirCoat, filtering takes place twice – with a slot filter in the high-pressure filter and with a filter in the gun. For ACF 3000 nozzles, the catalogue recommends:

  • slot filter: 200 mesh for orifices 07–11, 100 mesh for 11–17, 60 mesh for 17–23,
  • filter in the gun: 200 mesh for 07–11, 150 mesh for 11–13, 100 mesh for 13–19, 50 mesh for 19–23.

Nozzle wear: when to replace it

A worn nozzle uses more material than it should and sprays a poorer fan with more overspray. The orifice gradually enlarges due to the material: the fan narrows and the flow rate increases, so more paint goes onto a smaller area. According to WAGNER, the wear cannot be seen from the outside, so it only shows in the result and in paint consumption.

Replace the nozzle when the test spray does not turn out right even with the correct pressure and thinning, or when material consumption increases for the same work. For HEA nozzles, WAGNER states that a lower working pressure extends their service life by up to two times. According to WAGNER, AirCoat nozzles are made of carbide.

Reversible nozzles and nozzles with pre-atomiser

The PROTEC Tip reversible nozzle can be turned round so that a clogged orifice is blown clear by the material pressure itself without dismantling. The PROTEC range goes up to an orifice of 0.065″ (1.65 mm) with a flow rate of 9 l/min and is therefore used for high-build coatings.

The AirCoat ACF 3000 plus range has a pre-atomiser and its own orifice sizes from 08 to 22 with angles of 20–60°. The ACF 3000 S2 range, whose nozzles keep the same angle even after replacement, is designed for automatic lines, and the ACF 5000 range for electrostatic AirCoat guns. With manual AirCoat guns, the fan width can be fine-tuned with the shaping air.

From the part to the nozzle and filter

Start from the part and the material: the fan width determines the angle, the material and the required coat determine the orifice, and choose the filter to match the orifice. Tables for all ranges can be found in the WAGNER nozzles category. If you are not sure, send us the technical data sheet of the material and we will recommend a nozzle.

Is this an issue in your plant?

Tell us what you need – the technician for your area will get back to you.

Send an enquiry

Your technician

Peter Kovár

WAGNER Sales Manager | SK & CZ

Do you have a question on this topic?The AI adviser answers immediately

Frequently asked questions

What does the number on an Airless nozzle mean?

The number on an Airless nozzle indicates both the spray angle and the orifice size. The first digit multiplied by ten is the angle in degrees, the next two digits are the orifice diameter in thousandths of an inch. Nozzle 517 therefore has an angle of 50° and an orifice of 0.017″, which is 0.43 mm.

How does the spray angle relate to the fan width?

The spray angle determines how wide a fan the nozzle applies. WAGNER gives a rule of thumb: angle × 5 is the approximate spray width in millimetres at a distance of about 30 cm from the part. A nozzle with a 50° angle thus gives a fan roughly 25 cm wide.

When does an Airless nozzle need to be replaced?

A worn nozzle uses more material than it should and sprays a poorer fan with more overspray. The orifice gradually enlarges due to the material: the fan narrows and the flow rate increases, so more paint goes onto a smaller area. According to WAGNER, the wear cannot be seen from the outside, so it only shows in the result and in paint consumption.

Have a different question? Write to us – a technician will answer. Send an enquiry

Technical terms are explained in the glossary.

Send an enquiry

Just tell us what you know. The technician for your field will contact you and we will work out the rest together.

What do you need?

We carry out the trial at our site in Trnava or, by arrangement, at yours.

If your brand is not in the list, select “Other brand” and enter it in the description. We repair all types of spray equipment for which spare parts are still available.

Type or model, e.g. pump, gun or 2K system

From the equipment rating plate, if you know it

If you know it. Separate multiple items with commas.

Product, material, quantity or operation – anything that helps us prepare a quotation.

Photos (including from an iPhone), a video of the fault or the work, PDFs. Up to 5 files, 20 MB in total, and 2 videos up to 500 MB each. For painting, the technician almost always needs the technical data sheet of the coating; for recycling, the safety data sheet of the solvent. Videos are uploaded to storage in the EU right after you select them and are deleted automatically after 30 days.

Have you bought from us before? (optional)

Submitting this form is a non-binding enquiry. We will use your data only to handle it and prepare a quotation. Data controller: TECHNIKUM, s.r.o., Company ID {ico}, Coburgova 13, 917 02 Trnava. By sending your enquiry, you provide us with personal data, which we process in accordance with our privacy policy.

The technician for your field will contact you as soon as possible.

Call TECHNIKUM, +421 33 5521 123Send an enquiry