IST

IST C1-C2

Small IST C1 and C2 solvent recovery units for low and occasional solvent consumption – 1.6 kW, fill 10 or 15 l.

Who it is for: small workshops and paint shops, occasional solvent regeneration

  • 10–15 lLoading capacity (depending on version)
  • 10–60 l/24 hDistillation output
  • 1.6 kWOutput

Enquire about this productSend a solvent sample – we will test the recycling

The technician for your field will contact you as soon as possible. Prices are provided in our quotation.

Why IST C1-C2

  • Easy sludge removalTilting and practical sludge bags.
  • Simple operationHeating temperature and cycle time are regulated by rotary controls.
  • Small footprintCompact dimensions save production space.

C1 and C2 are small distillation units for companies with limited and occasional solvent consumption. They have static oil heating and manual operation, are safe and sturdy, and are easy to install and operate. Sludge is removed by tilting into practical bags; heating temperature and cycle time are regulated by rotary controls.

Source of text: manufacturer’s brochure (PDF, in English)

Technical data

Distillation output
10–60 l/24 h

Versions

Common to all versions

Output
1.6 kW
Differences between versions: IST C1-C2
VersionLoading capacityDistillation output
IST C110 l10–40 l/24 h
IST C215 l15–60 l/24 h

Data are taken from manufacturer documentation. We will verify them for your application before you order. Request a technical data sheet

How it works

How solvent distillation works

The contaminated solvent is heated in the boiler, its volatile fraction evaporates, turns back into a liquid in the condenser and flows out as clean solvent. The contaminants remain in the boiler as residue.

How solvent distillation worksContaminated solventVacuumBoilerOil heatingResidueCondenserAir / water coolingClean solvent
How solvent distillation worksContaminated solventVacuumBoilerOil heatingResidueCondenserAir / water coolingClean solvent
  • Contaminated liquid
  • Negative pressure (vacuum)
  • Heat
  • Residue for disposal
  • Vapour
  • Cooling
  • Clean liquid
Description of all parts
  1. Filling

    The contaminated solvent is filled into the boiler – depending on the machine, manually, with a filling kit or automatically from a storage tank.

    • Contaminated solvent
      Solvent contaminated with paints, resins and the like – for example from cleaning spray guns and containers.
  2. Heating and evaporation

    Thermal oil transfers heat to the boiler. The volatile fraction of the solvent evaporates; the less volatile contaminants remain in the boiler. Some series operate under vacuum.

    • Vacuum (some series)
      In some series (IST 90, IST 202, ECO PLUS, ROTO PLUS, HR), a vacuum pump lowers the boiling point of the solvent. IST uses a liquid-ring vacuum pump.
      A lower boiling point means less thermal stress – suitable for high-boiling and heat-sensitive solvents. For nitrocellulose paints, IST recommends vacuum distillation.
    • Distillation unit boiler: IST C1-C2
      A sealed boiler in which the solvent evaporates and the contaminants remain. Some series have an agitator with scrapers that keeps the boiler walls clean.
      Distillation only changes the physical state – the chemical properties of the solvent are retained, so it can be distilled repeatedly. IST has replaced the PTFE coating with a surface treatment of the boiler that is similarly non-stick and more wear-resistant.
      How solvent recycling by distillation works →
    • Thermal oil heating
      Heat is transferred to the boiler by thermal (diathermic) oil – not by a direct flame or a heating coil in the solvent.
      According to IST, oil heating is more efficient than steam or hot water. Smaller machines use static oil; the HR series has a modulating heater with an oil circulation pump.
  3. Condensation

    The vapours pass into the condenser, which removes their heat – the solvent returns to liquid form. The condenser is cooled by air or water.

    • Condenser
      Removes heat from the vapour so that the solvent turns back into a liquid.
      The condenser material must be compatible with the solvent being distilled.
    • Air or water cooling
      An air-cooled condenser depends on the room temperature and ventilation; a water-cooled one allows more stable conditions.
  4. Clean solvent

    The condensed solvent is collected in a container. Whether it is suitable for reuse depends on its composition and on the process in which it is to be used.

    • Clean solvent
      The distillate is collected in a container and can be reused, for example for cleaning.
      Less new solvent and less waste – and less dependence on suppliers.
  5. Residue

    At the end of the cycle, the concentrated residue is removed from the boiler – depending on the machine, by tilting the boiler into a bag, via a valve or automatically.

    • Residue for disposal
      The concentrated residue (sludge) from the boiler is disposed of as waste. Its volume is much smaller than that of the original contaminated solvent.
      The residue consists of resins, polymers, metals and other non-volatile substances; depending on its composition, it is hazardous waste. It is emptied by tilting the boiler into a bag (IST C, 32–62), via a valve (IST 90, 202) or automatically (HR).

Simplified principle, not the layout of a specific model. The filling, emptying and cooling method, and whether the machine operates under vacuum, vary by series – we specify them in our quotation.

Source: IST – description of the distillation process in 5 steps and the distillation unit pages (ist.it).

Similar models – IST distillation units

  • IST

    IST 32-62

    Small industrial IST 32 and IST 62 solvent recovery units for regular solvent consumption – fill 30 or 62 l, 30–240 l/24 h.

    30–240 l/24 hDistillation output

    Loading capacity
    30 – 62 l
  • IST

    ROTO NEXT 100-202-400

    IST ROTO NEXT 100-202-400 solvent distillation unit in ATEX II2G design – successor to ROTO PLUS with gravimetric filling and insulated vessel, 100 – 2,000 l/24 h.

    100–2,000 l/24 hDistillation output

    Loading capacity
    100 – 400 l
  • IST

    ROTO PLUS 100-202-400

    Modular self-cleaning IST ROTO PLUS 100-202-400 solvent distillation unit in ATEX II2G design – automatic unattended operation, 100 – 2,000 l/24 h.

    100–2,000 l/24 hDistillation output

    Loading capacity
    100 – 400 l
  • IST

    ECO PLUS 202-400

    Expandable IST ECO PLUS 202-400 solvent recovery unit in ATEX II2G version for continuous operation – up to 2,000 l of contaminated product per day.

    200–2,000 l/24 hDistillation output

    Loading capacity
    200 – 400 l

All products in this category

Frequently asked questions

How much solvent does IST C1-C2 recycle?

IST C1
According to the manufacturer's technical data for IST C1: throughput 10–40 l/24 h; filling volume 10 l.
IST C2
According to the manufacturer's technical data for IST C2: throughput 15–60 l/24 h; filling volume 15 l.

What is the installed power of IST C1-C2?

IST C1
According to the manufacturer's technical data for IST C1: installed power 1.6 kW.
IST C2
According to the manufacturer's technical data for IST C2: installed power 1.6 kW.

Have a different question? Write to us – a technician will answer. Send an enquiry

Technical terms are explained in the glossary.

Send an enquiry

Just tell us what you know. The technician for your field will contact you and we will work out the rest together.

What do you need?

We carry out the trial at our site in Trnava or, by arrangement, at yours.

If your brand is not in the list, select “Other brand” and enter it in the description. We repair all types of spray equipment for which spare parts are still available.

Type or model, e.g. pump, gun or 2K system

From the equipment rating plate, if you know it

If you know it. Separate multiple items with commas.

Product, material, quantity or operation – anything that helps us prepare a quotation.

Photos (including from an iPhone) and PDFs. Up to 5 files, 20 MB in total. For painting, the technician almost always needs the technical data sheet of the coating; for recycling, the safety data sheet of the solvent. Please send videos as a link or by e-mail.

Have you bought from us before? (optional)

Submitting this form is a non-binding enquiry. We will use your data only to handle it and prepare a quotation. Data controller: TECHNIKUM, s.r.o., Company ID {ico}, Coburgova 13, 917 02 Trnava. By sending your enquiry, you provide us with personal data, which we process in accordance with our privacy policy.

The technician for your field will contact you as soon as possible.

Call TECHNIKUM, +421 33 5521 123Send an enquiry